Features:
Construction:
Technical:
Installation Temperature: | 0°C to +60°C |
Operating temperature | -20°C to +75°C |
DC Resistance Unbalance | 5% |
Pair-to-Ground Capacitance Unbalance | 330 pF/100 m |
Capacitance | 14pF/ft nominal |
Pulling strength | 130 N |
Minimum bend radius | 4 outer cable diameters |
Velocity of Propagation | PE=65% |
Maximum Skew | 45ns@100 meters |
Dielectric Breakdown | 1000 Volts DC Conductor to Conductor |
Electrical:
Frequency, MHz | RL | Attenuation, dB | NEXT, dB | PSNEXT, dB | ELFEXT, dB | PSELFEXT, dB |
---|---|---|---|---|---|---|
0.772 | - | 1.8 | 67 | 64 | - | - |
1 | 20 | 2 | 65.3 | 62.3 | 63.8 | 60.8 |
4 | 23 | 4 | 56.3 | 53.3 | 51.7 | 48.7 |
8 | 24.5 | 5.8 | 51.8 | 48.8 | 45.7 | 42.7 |
10 | 25 | 6.5 | 50.3 | 47.3 | 43.8 | 40.8 |
16 | 25 | 8.2 | 47.3 | 44.3 | 39.7 | 36.7 |
20 | 25 | 9.3 | 45.8 | 42.8 | 37.7 | 34.7 |
25 | 24.3 | 10.4 | 44.3 | 41.3 | 35.8 | 32.8 |
31.25 | 23.6 | 11.7 | 42.9 | 39.9 | 33.9 | 30.9 |
62.5 | 21.5 | 17 | 38.4 | 35.4 | 27.8 | 24.8 |
100 | 20.1 | 22 | 35.3 | 32.3 | 23.8 | 20.8 |